This article will cover the procedure of adding/changing the oil of your compressor.
TABLE OF CONTENTS
Unsuitable oil or an insufficient or excessive amount of oil in the compressor could damage it.
- Before each use, check the oil level and, if applicable, add oil or drain off excess oil.
- Use multi-grade oils SAE 10W40/15W40.
- Perform a complete oil change no later than after 100 operating hours or 6 months.
Note: Used oil that ends up in the environment or the sewer system will pollute the environment.
- Only dispose of used oil as hazardous waste in accordance with valid local guidelines.
Use synthetic SAE 10W40 oil for operation at an ambient temperature of +5 °C to +40 °C. Synthetic oil has the advantage that its characteristics remain unchanged at different temperatures, e.g. in the summer or winter.
Checking the Oil Level
- Always check the oil level before you use the compressor.
- Check the oil level at the viewing window of the oil drain plug: The optimal oil level is between the “max.” mark and the “min.” mark (see figure below)
Draining the Oil
- This compressor is shipped with the synthetic oil SAE 10W40. Completely replace the oil after the first 100 hours of operation.
- To open the oil drain plug, you will need an AF 24 open-ended spanner (not included in the package contents).
- Make sure that the On/Off switch is set to the “OFF 0” position
- Before draining the oil, pull the mains plug out of the socket to disconnect the compressor from the power supply.
- Let the compressor cool off completely.
- Vent the compressor using the connected pneumatic tool.
- Have a collecting container ready to collect the old oil.
- Use the open-ended spanner to loosen the oil drain plug (see figure above, in the centre of the motor)
- If necessary, tip the compressor slightly and let the oil drain completely into the collecting container.
- Screw the oil drain plug back onto the compressor and use the open-ended spanner to tighten it again.
- Add new oil as described below.
Adding Oil
- Make sure that the On/Off switch is set to the “OFF 0”position
- Before adding oil, pull the mains plug out of the socket to disconnect the compressor from the power supply.
- Let the compressor cool off completely.
- Vent the compressor via the connected pneumatic tool.
- Screw the oil plug anticlockwise out of the threading of the oil fill opening. (See figure below)
- Add enough oil so that the oil level is between the “max.” and “min.” mark. (See figure above)
- Then screw the oil plug clockwise into the threading of the oil fill opening. (See figure below)